Roland Double Sheet Detector R1000 Series Manual page 93

Inductive principles – microcontroller based
Table of Contents

Advertisement

B0069991 / Rev. 1.7
System parameter 15: Specifying the system reaction when 2-sheet is detected.
System Parameter: 15
hold if 2-sheets
Fig. 86: Adjusting the 2-sheet reaction
Possible choices:
• no:
• yes:
System parameter 16: not available
System parameter 17: Setting the output logic (0-sheet, 1-sheet, 2-sheet and warning outputs).
System Parameter: 17
Output 0-1-2-warning
24V active
Fig. 87: Setting the output logic
Possible choices:
• 0 V:
• +24 V:
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector-series I20
no
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. The equipment does not block operation if double
sheet is encountered.
The outputs (0-sheet, 1-sheet and 2-sheet) are activated according to the number of
sheets between the sensors. If double sheet is detected, the output "2-sheet" is
activated and the equipment is blocked until the 2-sheet condition is cleared.
This condition can be cleared
- through the PLC (clear 2-sheet)
- through the keyboard
As shown in the timing diagrams and the wiring diagrams
The outputs 0-sheet, 1-sheet, 2-sheet and warning are inverted, i.e. the respective
signals in the timing diagrams and wiring diagrams must be seen inverted.
The output "Enable" is not affected thereby.
Note
Manual
Start-up
93