Sbus<N>:Manchester:trigger:pattern:value:data - Keysight Technologies InfiniiVision 4000 X Series Programmer's Manual

Hide thumbs Also See for InfiniiVision 4000 X Series:
Table of Contents

Advertisement

31
:SBUS<n> Commands
:SBUS<n>:MANChester:TRIGger:PATTern:VALue:DATA
Command Syntax
:SBUS<n>:MANChester:TRIGger:PATTern:VALue:DATA <string>
<string> ::= "nn...n" where n ::= {0 | 1 | X | $}
<string ::= "0xnn...n" where n ::= {0,..,9 | A,..,F | X | $}
When the VALue trigger mode is selected (:SBUS<n>:MANChester:TRIGger), the
:SBUS<n>:MANChester:TRIGger:PATTern:VALue:DATA command specifies the
value to trigger on.
Note that the trigger value bit order is always for bits as they arrive (that is, MSB
first) regardless of the serial decode bit order setting (in
:SBUS<n>:MANChester:BITorder).
The bit width (length) of the value is set with the
:SBUS<n>:MANChester:TRIGger:PATTern:VALue:WIDTh command.
Query Syntax
:SBUS<n>:MANChester:TRIGger:PATTern:VALue:DATA?
The :SBUS<n>:MANChester:TRIGger:PATTern:VALue:DATA? query returns the
specified trigger value as a string of binary digits.
Return Format
<string><NL>
<string> ::= "nn...n" where n ::= {0 | 1 | X | $}
See Also
1014
(see
page
1610)
":SBUS<n>:MANChester:BITorder"
":SBUS<n>:MANChester:TRIGger"
":SBUS<n>:MANChester:TRIGger:PATTern:VALue:WIDTh"
on page 1003
on page 1013
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
on page 1015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InfiniiVision 4000 X Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Infiniivision mso-x 4034aInfiniivision mso-x 4054aInfiniivision mso-x 4032aInfiniivision mso-x 4022aInfiniivision mso-x 4104aInfiniivision mso-x 4154a ... Show all

Table of Contents