:POWer:SIGNals:IEXPected

Command Syntax
:POWer:SIGNals:IEXPected <value>[suffix]
<value> ::= Expected current value in NR3 format
[suffix] ::= {A | mA}
The :POWer:SIGNals:IEXPected command specifies the expected inrush current
amplitude. This value is used to set the vertical scale of the channel probing
current.
Query Syntax
:POWer:SIGNals:IEXPected?
The :POWer:SIGNals:IEXPected query returns the expected inrush current setting.
Return Format
<value><NL>
<value> ::= Expected current value in NR3 format
See Also
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
(see
page
1610)
":POWer:INRush:APPLy"
":POWer:SIGNals:AUTosetup"
":POWer:SIGNals:OVERshoot"
":POWer:SIGNals:VMAXimum:INRush"
":POWer:SIGNals:SOURce:CURRent<i>"
":POWer:SIGNals:SOURce:VOLTage<i>"
on page 747
on page 776
on page 786
on page 787
on page 793