31
:SBUS<n> Commands
:SBUS<n>:MANChester:LOGic
Command Syntax
:SBUS<n>:MANChester:LOGic <logic>
<logic> ::= {FALLing | RISing}
The :SBUS<n>:MANChester:LOGic command specifies the polarity of the
Manchester signal:
• FALLing — specifies that a falling edge is used to encode a bit value of logic 1
• RISing — specifies that a rising edge is used to encode a bit value of logic 1.
Query Syntax
:SBUS<n>:MANChester:LOGic?
The :SBUS<n>:MANChester:LOGic? query returns the polarity setting.
Return Format
<logic><NL>
<logic> ::= {FALL | RIS}
See Also
•
•
•
•
1008
(see
page
1610)
(and a rising edge encodes a bit value of logic 0).
":SBUS<n>:MANChester:BASE"
":SBUS<n>:MANChester:BITorder"
":SBUS<n>:MANChester:IDLE:BITS"
":SBUS<n>:MANChester:STARt"
on page 1001
on page 1003
on page 1007
on page 1011
Keysight InfiniiVision 4000 X-Series Oscilloscopes Programmer's Guide
Need help?
Do you have a question about the InfiniiVision 4000 X Series and is the answer not in the manual?