Setting Coupling Channel; Blocked Dc Component Of Signal - Tenma 72-2650 Operating Manual

Digital storage oscilloscope
Hide thumbs Also See for 72-2650:
Table of Contents

Advertisement

72-2650/72-10510/72-8225A /72-8705A/72-8710A user manual
Pass through DC and AC
DC
Coupling
components of input signal.
Grounding
Disconnect input signal.
Limit bandwidth to 20MHz to reduce
Bandwidth
On
displayed noise. Full bandwidth.
Limited
Off
Turn off bandwidth limited.
Set vertical deflection factor by
Rough
coarse adjustment based on 1-2-5
adjustment
V/div
scale. Rough adjustment setting
range is further subdivided for fine
Fine
adjustments to improve vertical
adjustment
resolution.
Please set the probe compensation
10×
system ratio to match the probe
Probe
100×
attenuation coefficient of the probe
1000×
to be used.
Activate reverse function of
On
waveform. Waveform will be
Inverting
displayed reversely.
Waveform is displayed normally.
Off

Setting coupling channel

The following example shows how to change the coupling
of the input channel. If the measured signal connected to the
CH1 channel is a sinusoidal signal containing DC component,
press F1 to select AC coupling, to set the CH1 into AC
coupling mode. The DC component of the measured
signal is blocked.
The Waveform display is shown in the figure below.
Figure 2-1 Blocked DC Component of Signal
If you press F1 to select DC coupling, setting both
the DC and AC components of measured signals at
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

72-8225a72-8705a72-8710a72-10510

Table of Contents