Set The Trigger System; Trigger Type - Tenma 72-2650 Operating Manual

Digital storage oscilloscope
Hide thumbs Also See for 72-2650:
Table of Contents

Advertisement

pulse train width. As shown in Figure 2-13.
Figure 2-13 Trigger Hold-off for Synchronization
of Complex Waveform
The trigger setting of a DSO decides when the data
of the waveform starts to be collected and displays on
the screen. Once the trigger is correctly set, it can convert
unstable display into meaningful waveform display. Data
acquisition of a DSO starting trigger conditions satisfied.
After a signal trigger is detected, DSO will continuously
collect data and display the waveform on the right of the
24
72-2650/72-10510/72-8225A /72-8705A/72-8710A user manual
trigger point. The trigger control area of the DSO operation
panel includes: trigger level adjustment knob; trigger
menu key:
TRIG MENU for 72-10510/72-8225A/
72-8705A/72-8710A and [MENU] for 72-2650. For the
72-10510/72-8225A/72-8705A/72-8710A DSO, it can
set the trigger level to be at 50% of signal vertical midpoint
by the 50% button. For the 72-10510/72-8225A DSO, it
is achieved by pressing SET TO ZERO key. Forcing
trigger shall be achieved by pressing FORCE button.
FORCE trigger is a trigger signal generated by force
and is mainly applied in trigger mode and "normal" and
"single" mode.

2.3 Set The Trigger System

Trigger level knob: trigger knob is used to adjust the
trigger level (t o set the voltage level corresponding to
trigger point).

Trigger Type

72-2650/72-10510/72-8225A /72-8705A/72-8710A
DSO support: edge, pulse width, video trigger and alternative trigger;
Edge Trigger: Edge trigger mode refers to the triggering

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

72-8225a72-8705a72-8710a72-10510

Table of Contents