Measurement accuracy of voltage difference
(△V) (average sampling mode)
Note: the range of deflection factor for UTD 2025C is 2mV/div-10V/div (in the place of input BNC)

Bandwidth For Each Model

Model
72-2650
72-8710A
72-8705A
72-8225A
72-10510

Trigger System Specifications

Trigger sensitivity
Range of trigger level
54
72-2650/72-10510/72-8225A /72-8705A/72-8710A user manual
Under the same setting and environmental conditions and after averaging the
captured waveforms with a quantity of ≥16, the voltage difference (ΔV)
between any two points on the waveform: ± (3%×reading+0.05div)
Analog Bandwidth
Real-Time Bandwidth
200MHz
100MHz
50MHz
50MHz
25MHz
≤1div
Interior
EXT)
EXT/5*
Rise Time
100MHz
1.8ns
100MHz
3.5ns
50MHz
7ns
50MHz
7ns
25MHz
14ns
From the screen centre ±5div
±3V
±15V