System Fans
6.4
Replacing a Hot-plug System Fan Unit
The PRIMERGY RX800 S2 server comes with four 80-mm hot-plug fans in front
of the PCI-X slots and four 92-mm hot-plug fans in front of the memory cards
(overview: see figure 24 on page 109). The following removal and installation
procedures apply to either size fan.
V
CAUTION!
Defective fans should be replaced as soon as possible. Never leave a fan
bay empty for longer than two minutes during operation. Otherwise,
system components might be damaged because of excessive tempera-
tures.
I
When a fan fails or is removed, the other fans in the server speed up to
maintain a safe operating temperature in the server until the fan is
reinstalled or replaced. When the new fan is installed correctly, the fans
will slow down.
6.4.1
Removing a hot-plug fan
To remove a hot-plug fan, complete the following steps:
Ê Slide the server out of the rack until the slide rails lock into place.
Ê Remove the top cover (see "Removing the Cover" on page 108).
For the following steps, see figure 26 on page 113:
Ê Locate the defective fan unit (fan error LED is lit).
Ê Open the fan-locking handle by sliding the orange release latch in the
direction of the arrow.
Ê Pull upward on the free end of the handle to lift the fan out of the server.
6.4.2
Installing a hot-plug fan
To install the replacement hot-plug fan, complete the following steps:
Ê Open the fan-locking handle on the replacement fan.
Ê Lower the fan into the socket, and close the handle to the locked position.
Ê Reinstall the top cover and slide the server into the rack.