Replacing A Hot-Swap System Fan - Fujitsu PRIMERGY TX300 Operating Manual

Table of Contents

Advertisement

Hot-swap System Fan
Ê Carefully push the drive into the empty mounting location (1) until it stops.
Ê Push the handle completely in the direction of the arrow (2) until the locking
mechanism engages (3).
To remove the drive, follow the same procedure in the reverse order.
8.4

Replacing a Hot-swap System Fan

V
CAUTION!
The actions described in this section may only be performed by
personnel with the appropriate technical training. Any unauthorized
openings and improper repairs could expose the user to risks (electric
shock, fire hazards) and could also damage the equipment.
Please observe the safety information in chapter "Important Notes" on
page 13.
In order to replace a defective system fan, the left side cover (floorstand
model) or the housing cover (rack model) must be removed as the
system fans are not directly accessible (see section "Opening/Closing
the Housing" on page 97).
The failure of a system fan is notified by the Global Error indicator on the front
and rear of the server (lights orange).
The fan board shows which system fan has failed (figure 37 on page 91):
No. Position
1 Lower left fan, system fan 1
2 Upper left fan, system fan 2
Table 6: Arrangement of the system fans
The system fans 2 + 4 and the system fans 1 + 3 each form a redundant pair.
Ê Remove the left side cover (floorstand model) or the housing cover (rack
model) (see section "Opening/Closing the Housing" on page 97).
90
Hot-plug/hot-swap Components
No. Position
3
Lower right fan, system fan 3
4
Upper right fan, system fan 4
A26361-K881-Z102-4-7619