Installing the Server
Ê Pull the telescope bars completely out toward the front. They must click into
place so that you can no longer push them back.
Ê Lift the server onto the two projecting telescope bars (see figure 6), carrying
it by the handles.
To find the right mounting point, the two "teeth" protruding from the
i
upper side of the telescopic bars must match the two triangular marks
visible on each side of the server.
Figure 6: Lifting the server onto the two telescope bars
The following steps require only one person:
Ê Push the server approx. one inch (2 to 3 cm) into the rack until the locking
mechanism engages.
When locked in position, a blue indicator (1) is visible on each side of
i
the server.
Ê Remove the blue handles by unscrewing their wheels.
U41621-J-Z156-1-76
Mounting the Server in the Rack