Troubleshooting and Tips
Lit LED on
Cause
LED Card
LOG
Information is present in the
BMC log and system-error
log. One or both logs might
be full or almost full.
MEM
Memory failure.
i
NMI
A hardware error has been
reported to the operating
system (Non-maskable
interrupt occurred).
i
PCI
A PCI-X adapter has failed.
i
SP
There is a fault in the
Remote Service Adapter II.
Table 9: Indicators on the LED Card
U41621-J-Z156-1-76
The error LED on the
memory card is also
lit.
The PCI or MEM
LED might also be lit.
The error LED next
to the failing adapter
on the PCI-X adapter
is also lit.
Error Controls and Indicators
Action
Ê Save the log if necessary and
clear it (see "Event/Error Logs"
on page 61).
Ê Check the log for possible errors
(see "Event/Error Logs" on
page 61).
Ê Remove the memory card with
the lit error LED on the top of the
card; then, press the light path
button on the memory card to
identify the failed card or DIMM.
Ê If one of the DIMM error LEDs
on the memory card is on, have
system serviced.
Ê See the BMC log and the
system-error log (see
"Event/Error Logs" on page 61).
Ê If the PCI LED is lit, follow the
instructions for that LED.
Ê If the MEM LED is lit, follow the
instructions for that LED.
Ê Restart the server.
Ê If problem persists, have system
serviced.
Ê See the BMC log or the system-
error log (see "Event/Error
Logs" on page 61).
Ê If problem cannot be traced,
have the system serviced.
Ê Call for service.