Configuring the Server
Baseboard management controller (BMC) settings
Select this choice to view information and to change baseboard
management controller (BMC) settings.
– BMC firmware Version
This is a nonselectable menu item that displays the BMC firmware
version.
– BMC POST Watchdog
Enable or disable the BMC POST watchdog. Disable is the default
setting.
– BMC POST Watchdog Timeout
Set the BMC POST watchdog timeout value. 5 minutes is the default
setting.
– System BMC Serial Port Sharing
Enable or disable the system BMC serial port sharing. Enable is the
default setting.
– BMC Serial Port Access Mode
Share or disable the BMC serial port access mode. Shared is the default
setting.
– Reboot system on NMI
If you enable this option, the server automatically restarts 60 seconds
after the service processor issues a nonmaskable interrupt (NMI) to the
server. If you disable this option, the server does not restart. Enable is
the default setting.
– BMC Network Configuration
Select this choice to view the BMC Network Configuration information.
– BMC System Event Log
Select this choice to view the BMC system event log, which contains all
system error and warning messages that have been generated. Use the
arrow keys to move between pages in the log. The full text of the error
messages is displayed. Run the diagnostic program to get more infor-
mation about error codes that occur. Select Clear error logs to clear the
BMC system event log.