Replace Transducer O-Rings
1. Prepare Fluid Plate Assembly for Repair, page
84.
2. Remove the fluid outlet pressure sensor (117) from
the regulator (108).
F
. 58
IG
3. Press the transducer (CG) out of the retainer nut
(CH).
4. Remove the faulty o-ring (120) and replace with
new.
F
. 59
IG
5. Press the transducer back into the retainer nut.
6. Reconnect the fluid outlet pressure sensor to the
regulator.
3A2098S
117
r_pf0000_313377_16a
CH
CG
108
120
Repair