Graco PrecisionSwirl Instructions-Parts List Manual page 79

Precision dispense system
Table of Contents

Advertisement

Swirl Events and Errors
Event
Gateway
Code
Error No.
Event Name
CBR_
---
Swirl Communi-
cation Error
CDR_
---
Duplicate Module Duplicate Swirl Control
EAD_
---
Maintenance
Mode Entered
EBD_
---
Maintenance
Mode Exited
MBD_
---
Maintenance
Due - Orbiter
WBD_
---
Swirl Motor Fault Motor speed is outside
3A2098S
Event
Description
Event Type
Swirl Events and Errors
Swirl communication
Alarm
error with ADM
Alarm
DGM Detected
Maintenance mode
Advisory
entered
(self-clear-
ing)
Maintenance mode
Advisory
exited
(self-clear-
ing)
Maintenance due on
Advisory
swirl orbiter
Alarm
the +/- 50% tolerance
range for at least 5 sec-
onds while operating
Cause
The ADM lost commu-
Restore communica-
nication with the Swirl
tions
Control DGM
Two or more Swirl
Verify that all Swirl
Control DGMs have
Control DGMs have
the same rotary switch
proper rotary switch
setting
settings. Reset mod-
ule after changing
rotary switch setting.
Refer to Swirl Control
DGM section, page 22.
Swirl maintenance
No action required
mode entered
Swirl maintenance
No action required
mode exited
Swirl active time total-
Service Component
izer exceeded limit set-
ting
If necessary, reset
totalizer
Cable disconnected
Verify cable connec-
tions to swirl board,
swirl motor cable, and
swirl orbiter
Shorted motor cable
Replace swirl motor
(amber LED on swirl
cable (55 ft)
board will be on)
Orbiter bearing failure
Replace bearing
Motor defective
Replace swirl orbiter