Graco PrecisionSwirl Instructions-Parts List Manual page 72

Precision dispense system
Table of Contents

Advertisement

Errors
Event
Gateway
Code
Error No.
Event Name
EBUX
---
Download to
USB Complete
WSU0
---
USB configura-
tion error
WNC0
32
ADM Key Token
Error
WNG0
---
Gateway Map
Error
CBG0
---
Gateway Reset
WMG0 ---
Gateway Error
Detected
CBD_
---
Fluid Plate Com-
munication Error
CCG_
---
Fieldbus Com-
munication Error
Fluid Plate Events and Errors
Event
Gateway
Code
Error No.
Event Name
CAC_
---
CGM Communi-
cation Error
CAD_
---
Fluid Plate Com-
munication Error
B7C_
30
Style Out of
Range
72
Event
Description
Event Type
Control Center Events and Errors
Download to the USB is
Advisory
complete
(self-clearing)
USB configuration error Advisory
Missing or invalid key
Alarm
token
Missing or invalid map
Advisory
Gateway reset
Advisory
(self-clearing)
Gateway error
Alarm
detected; includes any
error not covered by
another more specific
error
Fluid Plate Communi-
Alarm
cation Error with ADM
Fieldbus Communica-
Alarm
tion Error
Event
Description
Event Type
Fluid Plate Events and Errors
Communication lost
Advisory
between CGM and
Fluid Plate
FCM lost communica-
Alarm
tion with the ADM
Style is out of range
Alarm
Cause
---
No action necessary
USB configuration
Reinstall system soft-
invalid or not present
ware on display
An ADM key token is
Verify the key token is
required to run the
installed
system
Verify the key token
part number is correct
for the PCF ADM
Missing or invalid
Install PCF map in
Gateway map
Gateway
Gateway setting(s)
Wait for reset to com-
changed
plete before attempt-
ing automation control
---
---
The ADM lost commu-
Restore communica-
nications with the
tion.
FCM.
The automation gate-
Restore communica-
way lost communica-
tions.
tion with the
automation controller.
Cause
Fluid Plate and CGM
Reconnect or replace
are no longer commu-
CAN cable
nicating
CGM is not functioning Replace the CGM if the
red status LED is solid
ADM is not communi-
Reconnect or replace
cating
CAN cable
ADM is not functioning Replace FCM if red
status LED is solid
ADM does not contain
Verify intended ADM
appropriate key token
key token is properly
inserted
Style requested by
Use a style number
automation controller
that is in range
exceeds number of
Increase number of
styles available on the
styles in PCF; pur-
fluid plate
chase accessory key
token
Solution
Solution
3A2098S