Graco PrecisionSwirl Instructions-Parts List Manual page 76

Precision dispense system
Table of Contents

Advertisement

Errors
Event
Gateway
Code
Error No.
Event Name
P3C_
70
High Pressure
P4C_
F1D_
71
Low Flow Rate
F2D_
F3D_
72
High Flow Rate
F4D_
EKD_
73
Shot Terminated
by Job Timer
EHD_
74
Purge Timer
Expired
EAC_
75
Maintenance
Mode Entered
EBC_
76
Maintenance
Mode Exited
MHD_
77
Maintenance
Due - Regulator
MFD_
78
Maintenance
Due - Flow Meter
76
Event
Description
Event Type
Fluid Plate Events and Errors
Measured outlet pres-
Alarm or
sure greater than
Deviation
desired outlet pressure
(user select-
plus tolerance
able)
Measured flow rate less
Alarm or
than desired flow rate
Deviation
minus tolerance
(user select-
able)
Measured flow rate
Alarm or
greater than desired
Deviation
flow rate plus tolerance
(user select-
able)
Shot dispense cycle
Advisory
terminated by job timer
Purge timer expired
Advisory
Maintenance mode
Advisory
entered
(self-clearing)
Maintenance mode
Advisory
exited
(self-clearing)
Maintenance due for
Advisory
regulator
Maintenance due for
Advisory
flow meter
Cause
Incorrect limit set
Verify limit is set cor-
rectly
Dispense hose/device
Clean/replace
plugged
hose/device
Failed transducer
Check transducer;
replace if failed
Regulator is not clos-
Repair regulator
ing completely when it
should
Fluid supply too low to
Increase fluid supply
achieve desired flow
pressure or check for
rate
clogged filter
Tip plugged
Clean/replace tip
No air pressure to
Turn on air to solenoid
solenoid valves
valves
No flow meter signal
Check cable and sen-
sor
No material supply
Replace drum or turn
on pumps
Incorrect flow toler-
Enter correct toler-
ance of flow error time
ance or flow error time
Operating below mini-
Increase fluid pres-
mum regulator operat-
sure above regulator
ing pressure
minimum
Regulator worn or not
Repair regulator
operating correctly
Flow meter providing
Replace flow meter
false pulses
sensor
Incorrect flow error tol-
Enter correct toler-
erance or flow error
ance or flow error time
time
Job end timer was
No action required if
used to stop shot dis-
timed shot is desired
pense
PCF purge timer (style
Automation control
0) has expired
requests purge
Entered maintenance
No action required
dispense mode
Exited maintenance
No action required
dispense mode
Totalizer exceeded
Service component
limit setting
If necessary, reset
totalizer
Totalizer exceeded
Service component
limit setting
If necessary, reset
totalizer
Solution