Appendix A - Advanced Display Module (ADM)
Fluid Plate x, Screen 3 (Delay Settings)
This screen enables users to set on and off delays (in
milliseconds) for each valve and the regulator
explanation of the on and off delays, refer to the On/Off
Delays section on page 43.
Fluid Plate x, Screen 4 (Control Loop and Flowmeter
Settings)
This screen enables users to set the meter type (volume
or mass) and the K-Factor for the flowmeter. Users can
also set the Kp, Ki, and Kd for the pressure control loop
as well as Kp and Ki for bead control loop.
NOTE: In systems without a flow meter, the flow meter
settings will be grayed out.
NOTE: It is recommended that these values not be
changed from the factory defaults of 32.00 for Kp,
128.00 for Ki, and 0.00 for Kd.
112
Fluid Plate x, Screen 5 (Pressure Sensors)
NOTE: Inlet sensor settings will be grayed out on this
.
screen for systems with heated fluid plates.
For an
This screen enables users to:
Set the offset for the inlet and outlet pressures.
NOTE: The offset value must be set to a non-zero
value before '-' can be selected from the +/-
drop-down menu.
Set the minimum and maximum pressure limits for
the inlet, and the maximum pressure limit for the
outlet.
Set the error type (alarm or deviation) that will be
issued if the inlet and/or outlet pressure go outside
of the set limits.
3A2098S