Graco PrecisionSwirl Instructions-Parts List Manual page 75

Precision dispense system
Table of Contents

Advertisement

Event
Gateway
Code
Error No.
Event Name
WFD_
63
Flow Meter
WFG_
Required
EJD_
64
Job Cycle Time
Out
WXD_
65
Fluid Plate Error
Detected
P3F_
66
Maximum Inlet
P4F_
Pressure
P3D_
67
Maximum Outlet
P4D_
Pressure
P1F_
68
Minimum Inlet
P2F_
Pressure
P1C_
69
Low Pressure
P2C_
3A2098S
Event
Description
Event Type
Fluid Plate Events and Errors
Operating mode
Alarm or
requires flow meter.
Advisory
Advisory is issued if
(self-clearing)
fluid plate settings
require a flow meter but
meter is not present.
Alarm is issued if dis-
pense is attempted in
mode that requires a
flow meter but meter is
not present.
Job cycle time out
Alarm
Fluid plate error
Alarm
detected; includes any
error not covered by
another more specific
error
Inlet pressure to regula-
Alarm or
tor is above upper limit
Deviation
set for operation
(user select-
able)
Outlet pressure of regu-
Alarm or
lator is above upper
Deviation
limit set for operation
(user select-
able)
Inlet pressure to regula-
Alarm or
tor is below lower limit
Deviation
set for operation
(user select-
able)
Measured outlet pres-
Alarm or
sure less than desired
Deviation
outlet pressure minus
(user select-
tolerance
able)
Cause
Selected valve mode
Check valve mode set-
settings require flow
tings
meter
Purchase meter
enabled token for FCM
and install flow meter
FCM key token miss-
Check for FCM key
ing or invalid
token error
Automation signals did
Check automation pro-
not properly end job
gramming per job
cycle
operating instruction
Analog voltage applied
Limit signal on pin 1 of
to pin 1 of the com-
command cable to the
mand cable exceeds
range of 0-10 Vdc.
10 Vdc.
Failed FCM
Replace FCM if neces-
sary
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Decrease material sup-
sure is too high
ply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Decrease material sup-
sure is too high
ply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect set limit
Verify limit is set cor-
rectly
Material supply pres-
Increase crease mate-
sure is too low
rial supply pressure
Failed transducer
Check transducer;
replace if necessary
Incorrect limit set
Verify limit is set cor-
rectly
No or insufficient
Increase material flow
material flow
rate
Dispense valve needle
Dislodge and inspect
is stuck closed
needle
Dispense valve leak-
Repair dispense valve
ing
Regulator not operat-
Repair regulator
ing correctly
Pump wink passed
Increase pump pres-
through outlet
sure
Failed transducer
Check transducer;
replace if failed
Errors
Solution
75