Graco PrecisionSwirl Instructions-Parts List Manual page 30

Precision dispense system
Table of Contents

Advertisement

Installation
Custom Breakout Cable
If desired, the following connector pinout information
may be used to build a custom breakout cable:
Pinout of FCM Port 1
Pin 1: Dispense Solenoid 4
Pin 2: Dispense Solenoid 2
Pin 3: Voltage - (common for all solenoids)
Pin 4: Dispense Solenoid 1
Pin 5: Dispense Solenoid 3
Dispense solenoid outputs are 24 Vdc. Dispense
solenoid outputs are capable of sourcing up to 0.5A
each (maximum 12W coil).
Install Command Cable Kit 24B694
Follow this procedure if using the command cable kit.
1. Install bulkhead fitting (included in the kit) into the
empty hole on the fluid plate. See F
page 29.
2. Connect one end of the extension cable (included in
the kit) to connection 5 on the FCM and the other
end of the cable to the bulkhead fitting.
3. Connect command cable to bulkhead fitting and
wire to automation controller per the following pinout
table.
FCM
Command
Port
Cable Wire
Pin #
Color
1
White
2
Brown
3
Green
4
Yellow
5
Gray
6
Pink
7
Blue
8
Red
NOTE: Command cable inputs are not isolated from
PCF 24 Vdc power.
*
To turn on the dispense trigger, connect the
dispense trigger pin to the dispense trigger ground
pin (pin 5).
30
. 19 on
IG
Dispense Trigger Source:
'Command Cable' or
'Combined'
Command voltage (0-10 Vdc)
No connection
Dispense trigger (*sourcing input)
No connection
Dispense trigger ground
No connection
Command signal ground
No connection
Function
Dispense Trigger Source:
'Command Cable 3x'
Command voltage (0-10 Vdc)
Valve 3 dispense trigger (*sourc-
ing input)
Valve 1 dispense trigger (*sourc-
ing input)
Valve 2 dispense trigger (*sourc-
ing input)
Dispense trigger ground
No connection
Command signal ground
No connection
3A2098S