Repair
6. Remove the din rail, filter, and rocker switch (snaps
into place). Replace with new components. Secure
din rail and filter to the rear control center assembly.
cover (1) using the four screws (40). Snap
rocker/rotary switch into position.
1
40
F
. 69: 24 Vdc Din Rail Assembly
IG
7. Reconnect all wiring to the din rail module, filter, and
rocker/rotary switch.
8. Reassemble the line voltage assembly cover using
the screws and washers.
Replace Fuses
Replace fuses on the din rail assembly.
•
For 24 Vdc control centers: see Technical Data
on page 148 for fuse specifications.
•
For 100-240 Vac control centers: Order fuse
115805.
F
. 70: Fuse Location
IG
94
40
40
r_pf0000_313377_10a
r_pf0000_313377_10a
Fuses
3A2098S