Graco PrecisionSwirl Instructions-Parts List Manual page 145

Precision dispense system
Table of Contents

Advertisement

Units Definitions
Unit s String
Command Value Source Enu-
meration
Dispense Control 1 Bitfield
Dispense Control 2 Bitfield
Dispense Trigger Source Enu-
meration
Error Type Enumeration 1
Fault Error Code
Flow Meter Type Enumeration
Fluid Plate Status 0 Bitfield
Fluid Plate Status 3 Bitfield
Job End Mode Enumeration
Maintenance Units Enumeration 0 - Volume, 1 - Mass, 2 - Time
Mass Units Enumeration
Precharge Settings Type
Pressure Units Enumeration
Rate Units Enumeration
sint32
Speed Source Enumeration
STR_X_Y
Swirl Control Enumeration
Swirl Enumeration
Swirl Status Bitfield 1
Tolerances Type
Valve Mode Enumeration
uint12
uint32
Version
Volume Units Enumeration
3A2098S
Appendix C - Communications Gateway Module (CGM) Connection Details
Definition
0 - Display, 1 - Command Cable, 2 - Gateway
Bit .........Function
0 ............Style Strobe
1 ............Dispense Complete
2 ............Valve 1 On
Bit 14 - Error Reset, Bit 15 - Remote Start
0 - Command Cable, 1 - Gateway, 2 - Combined, 3 - Command Cable 3x
0 - None, 1 - Alarm, 2 - Deviation
A 32-bit string in the format of 0xDDCCBBAA where 0xAA represents the most significant
ASCII character in the string and 0xDD represents the least significant character in the string.
1 - Volume, 2 - Mass
Bit .........Function
0 ............Dispenser Ready
1 ............Dispense No Alarm
2 ............Dispense No Error
Bit .........Function
0-2 .........Operation Mode (see Valve
Mode Enumeration)
3 ............Precharge Active
4 ............Valve 1 State
5 ............Valve 2 State
6 ............Valve 3 State
7 ............Valve 4 State
8 ............Ready to Dispense
9 ............In Job Cycle
10 ..........Job Cycle Complete
0 - Timer, 1 - Gateway
0 - lb, 1 - kg
A 32 bit value in the format of 0xDDCCBBA:
0xA........Precharge mode enumeration: 0 - Display, 1 - Gateway, 2 - Valve 1
0xBBB...Precharge valve opening duration (ms)
0xCC.....Precharge scale - valve closed (%)
0xDD.....Precharge scale - valve opening (%)
0 - psi, 1 - bar, 2 - MPa
0 - x/min, 1 - x/sec
A 32 bit positive or negative value
0 - Display, 1 - Gateway
A 32 bit value where X signifies which character in the string that the most significant byte rep-
resents and Y signifies which character in the string that the least significant byte represents.
0 - Swirl Enable
0 - None, 1 - Swirl 1, 2 - Swirl 2, 3 - Swirl 3, 4 - Swirl 4
0 - Swirl Active, 1 - Swirl Ready, 2 - Swirl Enabled
A 32 bit value in the format of 0x0000BBAA where 0xAA represents the low tolerance (%) and
0xBB represents the high tolerance (%). A value of 0 means that tolerance is disabled.
0 - Pressure, 1 - Bead, 2 - Shot, 3 - Full Open, 5 - None
A 12 bit positive value
A 32 bit positive value
A 32 bit value in the format of 0x00CCBBAA where 0xAA represents the major version, 0xBB
represents the minor version and 0xCC represents the build version.
0 - gal(US), 1 - gal(UK), 2 - Liters
3 ............Valve 2 On
4 ............Valve 3 On
5 ............Valve 4 On
3 ............Dispense In Process
4 ............Dispensed Volume OK
5 ............---
6 ............Dispenser Purge Request
11 ......... Alarm Active
12 ......... Deviation Active
13 ......... Advisory Active
14 ......... Dispensing Disabled
15 ......... Fluid Plate Enabled
16 ......... Flowmeter Enabled
17 ......... Inlet Sensor Enabled
18 ......... Heated Plate
19 ......... Integrator Enabled
22 ......... Valve 1 Swirl Installed
23 ......... Valve 2 Swirl Installed
6 ............Error Reset
7 ............Remote Start/Purge
7 ............Purge in Process/Remote
Start in Process
24 ......... Valve 3 Swirl Installed
25 ......... Valve 4 Swirl Installed
26 ......... Valve 1 Swirl Active
27 ......... Valve 2 Swirl Active
28 ......... Valve 3 Swirl Active
29 ......... Valve 4 Swirl Active
30 ......... Fault Reset
31 ......... Remote Start/Purge
145