Graco PrecisionSwirl Instructions-Parts List Manual page 140

Precision dispense system
Table of Contents

Advertisement

Appendix C - Communications Gateway Module (CGM) Connection Details
Output
Bits
256-267 Description
0x007
Software Part
Number
0x008
Software Ver-
sion
0x0DD
Maintenance
Units Type
0x0DF
Enabled Styles ###
0x203
Purge Period
0x204
Dispense Trig-
ger Source
0x208
Command
Value Source
0x20F
Bead Scale
0x210
Job End Mode Job End Mode Enu-
0x211
Job End Delay
Time
0x2B5
End Job On
Alarm
0x212
Valve 1 Enable Boolean
0x213
Valve 2 Enable Boolean
0x214
Valve 3 Enable Boolean
0x215
Valve 4 Enable Boolean
0x216
Regulator On
Delay
0x217
Regulator Off
Delay
0x218
Valve 1 On
Delay
0x219
Valve 2 On
Delay
0x21A
Valve 3 On
Delay
0x21B
Valve 4 On
Delay
0x21C
Valve 1 Off
Delay
0x21D
Valve 2 Off
Delay
0x21E
Valve 3 Off
Delay
0x21F
Valve 4 Off
Delay
0x230
Flow Meter
Type
140
Units
*See Units
Read or
Definitions, page 145
Write
STR_15_12
Read Only
Version
Read Only
Maintenance Units
Read Only
Enumeration
Read Only
#### (minutes)
Read /
Write
Dispense Trigger
Read /
Source Enumeration
Write
Command Value
Read /
Source Enumeration
Write
### (percent)
Read /
Write
Read /
meration
Write
Integer (Seconds)
Read /
Write
Boolean
Read /
Write
Read /
Write
Read /
Write
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
### (mS)
Read /
Write
Flow Meter Type Enu-
Read /
meration
Write
Output
Units
Bits
*See Units
256-267 Description
Definitions, page 145
0x231
Flow Meter
##### (pulses/Liter,
K-Factor
pulses/kg)
0x23C
Outlet Pres-
sint32; #### (psi);
sure Sensor
###.# (bar); ##.##
User Offset
(Mpa)
0x23D
Inlet Pressure
sint32; #### (psi);
Sensor User
###.# (bar); ##.##
Offset
(Mpa)
0x241
Maximum Out-
uint32; #### (psi);
let Pressure
###.# (bar); ##.##
(Mpa)
0x244
Minimum Inlet
uint32; #### (psi);
Pressure
###.# (bar); ##.##
(Mpa)
0x245
Maximum Inlet
uint32; #### (psi);
Pressure
###.# (bar); ##.##
(Mpa)
0x248
Pressure Kp
####.##
0x249
Pressure Ki
####.##
0x247
Pressure Kd
####.##
0x254
Bead Kp
####.##
0x255
Bead Ki
####.##
0x260
Regulator Time
###### (hours)
Advisory Limit
0x262
Regulator Vol-
Volume: ######
ume/Mass
(gal(US)); ######
Advisory Limit
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
0x264
Flow meter
###### (hours)
Time Advisory
Limit
0x266
Flow meter
Volume: ######
Volume/Mass
(gal(US)); ######
Advisory Limit
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
0x268
Supply Time
###### (hours)
Advisory Limit
0x26A
Supply Vol-
Volume: ######
ume/Mass
(gal(US)); ######
Advisory Limit
(gal(Uk)); ######
(Liters); Mass: ######
(lb), ###### (kg)
0x26C
V/P Time Advi-
###### (hours)
sory Limit
Read or
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
Read /
Write
3A2098S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pcf