Appendix C - Communications Gateway Module (CGM) Connection Details
PROFIBUS
OP
5
DC
F
. 75: PROFIBUS Fieldbus Connections
IG
Operation Mode (OP)
State
Off
Not online / No power
Green
On-line, data exchange
Flashing
On-line, clear
Green
Flashing Red
Parameterization error
(1 flash)
Flashing Red
PROFIBUS Configuration error
(2 flashes)
Status Mode (ST)
State
Off
No power or not initialized
Green
Initialized
Flashing
Initialized, diagnostic event(s) present
Green
Red
Exception error
130
4
3
2
1
9 8 7 6
TI11816A
Description
Description
PROFIBUS Connector (DC)
Pin
Signal
ST
1
-
2
-
3
B Line
4
RTS
5
GND Bus
6
+5V Bus
Output
7
-
8
A Line
9
-
Housing Cable
Shield
Description
-
-
Positive RxD/TxD, RS485 level
Request to send
Ground (isolated)
+5V termination power (isolated)
-
Negative RxD/TxD, RS485 level
-
Internally connected to the Anybus
protective earth via cable shield filters
according to the PROFIBUS stan-
dard.