Errors
Event
Gateway
Code
Error No.
Event Name
WED_
55
V/P Error
WJ1_
56
Dispense Valve 1
Error
WJ2_
57
Dispense Valve 2
Error
WJ3_
58
Dispense Valve 3
Error
WJ4_
59
Dispense Valve 4
Error
WSD_
60
Incompatible
Valve Settings
WSD5
60
Incompatible
Valve Settings
F7D_
61
Closed Valve
Flow
V2D_
62
Low Analog
74
Event
Description
Event Type
Fluid Plate Events and Errors
Voltage to Pressure
Alarm
Transducer error
Dispense valve 1 error
Alarm
Dispense valve 2 error
Alarm
Dispense valve 3 error
Alarm
Dispense valve 4 error
Alarm
Incompatible settings
Alarm
for multiple valve oper-
ation; attempted to dis-
pense
Incompatible settings
Alarm
for multiple valve oper-
ation; attempted to dis-
pense
System reading flow
Alarm
meter pulses with
valve(s) closed
Command cable ana-
Deviation
log command dropped
below minimum value
of 1 V while dispensing
Cause
Problem detected with
Verify outlet pressure
V/P
transducer is installed
and/or connected cor-
rectly
Replace if necessary
Problem detected with
Verify dispense valve 1
dispense valve 1
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 2
dispense valve 2
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 3
dispense valve 3
is installed and/or con-
nected correctly
Replace if necessary
Problem detected with
Verify dispense valve 4
dispense valve 4
is installed and/or con-
nected correctly
Replace if necessary
Attempted to dis-
Check settings shown
pense simultaneously
on Fluid Plate x,
from multiple valves
screen 2 (Mode Set-
on the same fluid plate
tings)
with different pressure
Verify automation pro-
settings
gramming
Attempted to dis-
In the Discrete Gate-
pense simultaneously
way screens, change
from multiple valves
the settings of the
on the same fluid plate
simultaneously dis-
with different pressure
pensing valves to the
settings
same pressure
Verify automation pro-
gramming
Dispense hose leak
Check hose; replace if
needed
Flow meter providing
Replace flow meter
false pulses
sensor or calibrate
meter
Dispense valve not
Repair dispense valve
operating correctly
Bad or loose com-
Check command cable
mand cable connec-
and connection
tion
Entered command
Enter correct com-
mode incorrectly
mand code
Automation program
Verify correct automa-
error
tion program