Critical Installations
The meters must be mounted at the highest point of the
tubing (A), if gas bubbles are to be expected, or at the
lowest point (B), if solid particles are to be expected, as
in both cases also the right orientation might not help.
F
. 18.
IG
Mount Four-Valve Breakout Kit 24B693
PCF is capable of controlling up to four separate
dispense valves from port 1 on the FCM. A four-valve
breakout kit (24B693) is available to split the dispense
solenoid connector (port 1 on the FCM) into four
separate dispense solenoid connectors. For each
additional dispense valve, order one dispense valve
solenoid (258334) and one solenoid cable (121806).
Follow this procedure if using the four-valve breakout
kit.
1. Remove the existing dispense solenoid and cable
from the fluid plate.
3A2098S
2. Install bulkhead fitting (included in the kit) into the
empty hole on the fluid plate.
Connection 1
Splitter Assembly
F
. 19: Mount Breakout Kit
IG
3. Connect one end of the extension cables (included
in the kit) to connection 1 on the FCM and the other
end of the cable to the bulkhead fitting.
4. Connect the splitter assembly to the bulkhead fit-
ting.
5. Connect the dispense valve cable(s) to the
connections on the splitter assembly.
Cable for:
Dispense Valve 1
Dispense Valve 2
Dispense Valve 3
Dispense Valve 4
6. Mount splitter assembly and dispense valves, and
connect air lines as necessary for application.
Installation
GCA Cable
Hole for bulk-
head fitting
J1
J3
J2
J4
Connects to Splitter
Connection Labeled:
J1
J2
J3
J4
29