Fluid Plate x, Screen 6 (Error Type)
This screen enables users to set the error type (none,
alarm, or deviation) that will be issued if the pressure,
flow rate, volume, or computed target goes outside the
tolerance settings of the active style. See Configure
Errors on page 40.
NOTE: Only the low/high pressure errors will be
enabled for systems without a flow meter.
The pressure and flow rate errors are relative to the
value commanded (through the command cable,
gateway or display)
The volume is relative to the requested volume and
computed target errors are relative to the target
volume defined in the style
3A2098S
Appendix A - Advanced Display Module (ADM)
Fluid Plate x, Screen 7 (Maintenance Advisory
Limits)
This screen enables users to set volume (or hours) limit
that will trigger a maintenance advisory for the air sup-
ply, voltage to pressure (V/P) transducer, fluid regulator,
flow meter, and all four valves.
NOTE: Hours is shown instead of Volume for fluid plates
without a flow meter.
The Volume (or Hours) column displays the current
totalizer value. If this value exceeds the set limit, the
value will turn red and a maintenance advisory is issued.
See Fluid Plate x, Screen 3 (Maintenance Totalizers),
page 119, for more information about maintenance total-
izers.