Graco PrecisionSwirl Instructions-Parts List Manual page 78

Precision dispense system
Table of Contents

Advertisement

Errors
Event
Gateway
Code
Error No.
Event Name
CR3_
90
Valve 3 Swirl
Communication
Error
CR4_
91
Valve 4 Swirl
Communication
Error
WD1_
92
Valve 1 Swirl
Fault
WD2_
93
Valve 2 Swirl
Fault
WD3_
94
Valve 3 Swirl
Fault
WD4_
95
Valve 4 Swirl
Fault
MB1_
96
Maintenance due
- V1 Orbiter
MB2_
97
Maintenance due
- V2 Orbiter
MB3_
98
Maintenance due
- V3 Orbiter
MB4_
99
Maintenance due
- V4 Orbiter
78
Event
Description
Event Type
Fluid Plate Events and Errors
Fluid plate communica-
Alarm
tion error with swirl
Fluid plate communica-
Alarm
tion error with swirl
Swirl motor fault
Alarm or
Deviation
(user-select-
able)
Swirl motor fault
Alarm or
Deviation
(user-select-
able)
Swirl motor fault
Alarm or
Deviation
(user-select-
able)
Swirl motor fault
Alarm or
Deviation
(user-select-
able)
Maintenance due on
Advisory
valve 1 swirl orbiter
Maintenance due on
Advisory
valve 2 swirl orbiter
Maintenance due on
Advisory
valve 3 swirl orbiter
Maintenance due on
Advisory
valve 4 swirl orbiter
Cause
The fluid plate lost
Restore communica-
communication with
tions.
the swirl zone associ-
ated with this valve
and fluid plate
The fluid plate lost
Restore communica-
communication with
tions.
the swirl zone associ-
ated with this valve
and fluid plate
The swirl zone associ-
Resolve swirl motor
ated with this valve
fault (see error WBDX
and fluid plate caused
for possible solutions)
a fault
The swirl zone associ-
Resolve swirl motor
ated with this valve
fault (see error WBDX
and fluid plate caused
for possible solutions)
a fault
The swirl zone associ-
Resolve swirl motor
ated with this valve
fault (see error WBDX
and fluid plate caused
for possible solutions)
a fault
The swirl zone associ-
Resolve swirl motor
ated with this valve
fault (see error WBDX
and fluid plate caused
for possible solutions)
a fault
The active time total-
Service Component
izer for the swirl dis-
penser associated
If necessary, reset
with this valve and
totalizer
fluid plate exceeded
limit setting
The active time total-
Service Component
izer for the swirl dis-
penser associated
If necessary, reset
with this valve and
totalizer
fluid plate exceeded
limit setting
The active time total-
Service Component
izer for the swirl dis-
penser associated
If necessary, reset
with this valve and
totalizer
fluid plate exceeded
limit setting
The active time total-
Service Component
izer for the swirl dis-
penser associated
If necessary, reset
with this valve and
totalizer
fluid plate exceeded
limit setting
Solution
3A2098S