41.2.4 Setting Serial Port
Syntax [no] port <SERIAL-PORT>
Context
Modbus Gateway Configuration
Usage Set serial port, e.g., use "port 1" to select serial port 1 on a single slot
unit, or "port 1/1" to select serial port 1 in slot 1 of a slotted WeOS unit.
You can use the "show serial" command in Admin Exec (see
mode to list information about your serial ports, including the serial port
numbers.
Use "no port" to deselect the defined serial port.
Note
The Modbus Gateway will not be activated if no serial port is defined.
Use "show port" to show the Modbus Gateway port setting.
Default values Disabled ("no port")
41.2.5 Setting Serial Protocol
Syntax [no] serial-protocol <rtu|ascii>
Context
Modbus Gateway Configuration
Usage Use "serial-protocol rtu" or "serial-protocol ascii" to specify
use of RTU or ASCII as serial protocol respectively.
Use "no serial-protocol" to reset the serial protocol to default (RTU).
Use "show serial-protocol" to show the serial protocol setting.
Default values RTU ("serial-protocol rtu")
41.2.6 Setting listen interface and port
Syntax [no] listen iface <IFNAME|any> [port <PORT>]
Context
Modbus Gateway Configuration
1054
Westermo OS Management Guide
context
context
context (server mode only)