Westermo RedFox Series Management Manual page 1012

Westermo os
Hide thumbs Also See for RedFox Series:
Table of Contents

Advertisement

39.3.6 Setting Software flow control (XON/XOFF)
Syntax [no] xonxoff
Context
Serial Port Configuration
Usage Enable/disable software flow control using XON/XOFF
Use "show xonxoff" to show the software flow control setting (XON/XOFF)
for this serial port.
Default value Disabled (no xonxoff)
39.3.7 Setting Hardware flow control (RTS/CTS)
Syntax [no] rtscts
Context
Serial Port Configuration
is operating in RS-232 mode)
Usage Enable/disable hardware flow control using RTS/CTS.
Use "show rtscts" to show the hardware flow control setting (RTS/CTS) for
this serial port.
Default value Disabled (no rtscts)
39.3.8 Selecting serial protocol for a serial (combo) port
Syntax [no] type <rs232|rs422|rs485>
Context
Serial Port Configuration
and RS-422/485 "combo" serial ports. )
Usage Select serial protocol to use for a serial (combo) port. Use, e.g., "type
rs422" to make a port operate in RS-422 mode. "no type" resets to the
default type (RS-232 for RS-232/422/485 ports and RS-485 for RS-422/485
ports).
Use "show type" to show whether the serial (combo) port is configured in
RS-232, RS-422, or RS-485 mode. (This is only of major interest for combo
RS-232/422/485 and RS-422/485 serial ports - a "regular" RS-232" serial
port cannot be set to anything but RS-232.)
1012
Westermo OS Management Guide
context
context (only applicable when the serial port
context (Only applicable to RS-232/422/485
© 2018 Westermo Teleindustri AB
Version 4.24.1-0