The below explanations refer to the ordering form.
Power sizes (positions 1-6):
0,37 HP (kW) - 3,3 HP (kW) (See power
size selection table)
Application range (position 7):
P-process
Electrical voltage (positions 8-9):
T4 - 380-480 V three phase supply voltage
Enclosure (positions 10-12):
The enclosure offers protection against dusty,
wet, and aggressive environment
P66 - Protected IP66 enclosure
Hardware variant (positions 13-14):
ST - Standard hardware
EX - 24 V external supply for backup of control card
EB - 24 V external supply for backup of control
card, control and supply of mechanical brake
and an additional brake chopper
RFI filter (positions 15-16):
R1 - Compliance with class A1 filter
Display unit (LCP) (positions 17-18):
Connection possibility for display and keypad
D0 - No pluggable display connector in the unit
DC - Display connector plug mounted (not available
with "only right side" installation box variants)
Fieldbus option card (positions 19-21):
A wide selection of high performance fieldbus
options is available (integrated)
F00 - No fieldbus option built in
F10 - Profibus DP V0/V1 3 Mbaud
F12 - Profibus DP V0/V1 12 Mbaud
F30 - DeviceNet
F70 - AS-interface
MG.90.F2.22 - VLT is a registered Danfoss trademark
Decentral Solutions
Installation box (positions 22-24):
T00 - No Installation box
T11 - Installation box, motor mount, metric
thread, only right side
T12 - Installation box, motor mount, metric
thread, double side
T16 - Installation box, motor mount, NPT
thread, double side
T22 - Installation box, motor mount, metric
thread, double side, service switch
T26 - Installation box, motor mount, NPT thread,
double side, service switch
T51 - Installation box, wall mount, metric
thread, only right side
T52 - Installation box, wall mount, metric
thread, double side
T56 - Installation box, wall mount, NPT
thread, double side
T62 - Installation box, wall mount, metric thread,
double side, service switch
T66 - Installation box, wall mount, NPT thread,
double side, service switch
T63 - Installation box, wall mount, metric thread,
double side, service switch, sensor plugs
T73 - Installation box, wall mount, metric thread,
double side, motor plug, sensor plugs, Viton gasket
Coating (positions 25-26):
The IP66 enclosure offers protection of the drive against
aggressive environments, which practically eliminates
the need for coated printed circuit boards.
C0 - Non-coated boards