ControlNet Objects
DPI Parameter Object
Format for Set_Attributes_Scattered Service
The structure shown below can get up to twenty-two parameters in a
single message. In the Response Message, a parameter number with the
high bit set indicates that the associated pad word field contains an error
code.
Word 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
...
63
64
65
Request
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
Parameter Number
Parameter Value LSW
Parameter Value MSW
(Continued)
Word 0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
...
63
64
65
Response
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word or Error Code
Pad Word
Parameter Number
Pad Word