Installation Instructions Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Catalog Numbers 2711P-RAAT7, 2711P-RAAK7, 2711P-RAAT10, 2711P-RAAK10, 2711P-RAAT12, 2711P-RAAT12K, 2711P-RAAT15, 2711P-RAAK15 Topic Page Summary of Changes Before You Begin Remove the Existing Terminal From the Panel Drill the Holes for the Adapter Kit...
Replace this Existing PanelView Plus 6 or Plus 7 Performance Template Cat. No. PanelView Standard Terminal… Terminal Cat. No. 2711P-RAAT7 PanelView Plus 6 700 touch screen 6.5-in. touch screen 2711P-RAAK7 • PanelView Plus 6 700 keypad, or keypad with touch screen 6.5-in. keypad VIEW-DS002 •...
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Remove the Existing Terminal From the Panel ATTENTION: Remove all power from the components in the enclosure and the existing terminal. Disconnect the communication cables from the terminal. Failure to remove all power and disconnect communication cables can cause electric shock and unexpected communication signals to the machinery.
Page 5
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 3. Cut out the center white space and the white edges of the drill template, and leave the shaded part of the template that includes the drill locations. 4. Center the drill template over the existing cutout in the panel. Align the edge of the existing panel cutout with the interior edge of the drill template.
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Install the Adapter Plate and Backing Plate Before you install the adapter and backing plate, measure the thickness of the panel to find the correct mounting lever lock position for the new terminal installation. Determine the Mounting Lever Lock Position Mounting Lever Lock...
Page 7
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 6. Follow the tightening sequence on page for your terminal adapter kit. ATTENTION: To maintain a NEMA Type 4X rating, torque the nuts to 3.90 N•m (30 lb•in). Rockwell Automation is not responsible for water or chemical damage to the terminal, or other equipment within the panel, due to improper installation.
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Prepare to Mount the Terminal Mounting levers insert into the slots around the terminal bezel to secure the terminal in the adapter plate. The number of mounting levers varies by terminal size. Each slot has six notches with alignment marks that are locking positions for a mounting lever.
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Mount the Terminal Installing the mounting levers is a multi-step process. Step installs each lever so that the terminal is snug in the adapter plate and the gasket is slightly compressed. Step moves the mounting levers into tighter locking positions until you reach the final locking position that you previously marked with a marker or grease pencil.
Page 10
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 5. Insert the remaining levers in the terminal and rotate each lever until the flat side is in contact with the backing plate and the gasket is slightly compressed. IMPORTANT Install the mounting levers by the orientation sequence shown in Mounting Lever...
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 7. Inspect all mounting levers and verify that each lever is in the correct locked position. ATTENTION: All mounting levers must be in the correct locked position and follow the correct lever installation sequence to provide an adequate gasket seal between the terminal and the adapter plate.
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals Drill Template Dimensions This section includes the layout dimensions for the drill locations of the adapter kit. 6.5-in. Only Touch – Catalog Number 2711P-RAAT7 NOTE: All dimensions are in mm (in.) 257 (10.11) 220 (8.66)
Page 13
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 10.4-in. Only Touch – Catalog Number 2711P-RAAT10 NOTE: All dimensions are in mm (in.) 305 (12.0) (10.78) (3.74) (8.82) (3.74) (4.4) 25 (0.98) 6.35 (0.25) (3.74) (3.74) 17.5 120.5 (4.74) 279.5 (11.0) 340 (13.39) 10.4-in.
Page 14
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 12.1-in. Only Touch – Catalog Number 2711P-RAAT12 NOTE: All dimensions are in mm (in.) 43.5 (1.71) (13.31) (11.54) (3.74) (10.12) (3.74) 128.5 (5.06) (0.71) 95 (3.74) 95 (3.74) 6.35 (0.25) 21 (0.83) 169 (6.65) 359 (14.13)
Page 15
Adapter Kit for PanelView 5000 and PanelView Plus 7 Performance Terminals 15-in. Only Touch – Catalog Number 2711P-RAAT15 NOTE: All dimensions are in mm (in.) 444 (17.48) 391 (15.39) 85 (3.35) 85 (3.35) (3.74) (13.43) (12.0) (3.74) 152.5 (6.0) (0.71) 26.5 15.5 (0.61) (1.04)
Provides declarations of conformity, certificates, and other certification rok.auto/certifications details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.