Installation Instructions
Quick Start Guide for Configuring an E3
Plus EtherNet/IP Adapter
Catalog Numbers 2100-ENET
Topic
Page
2
3
3
4
4
4
7
9

Advertisement

loading
Need help?

Need help?

Do you have a question about the 2100-ENET and is the answer not in the manual?

Questions and answers

Summary of Contents for Allen-Bradley 2100-ENET

  • Page 1: Table Of Contents

    Installation Instructions Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter Catalog Numbers 2100-ENET Topic Page Important User Information Additional Resources Components Status Indicators Introduction Set the IP Network Address Install EDS File Logix Controller I/O Messaging...
  • Page 2: Important User Information

    2 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter Important User Information Solid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid-state equipment and hard-wired electromechanical devices.
  • Page 3: Additional Resources

    Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/literature/. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. Components Components of the Adapter...
  • Page 4: Status Indicators

    4 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter Status Indicators The adapter uses four status indicators to report its operating status. Status Indicators Status Indicators Item Name Color State Description PORT Green Flashing Normal Operation. The adapter is establishing an I/O connection to the E3 Plus overload relay.
  • Page 5 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter 5 2. Select Tool > Network Settings and enter the subnet mask for the network. If appropriate for the network, enter the gateway address, primary/secondary server addresses, and domain name. 3.
  • Page 6 6 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter 5. Enter the IP address for the adapter and, if appropriate, enter the host name and an adapter description. 6. Click OK. Once the IP address you entered shows up in the Request History panel (you may need to cycle power to the adapter), this configuration can be permanently assigned to the adapter.
  • Page 7: Install Eds File

    (Leave Blank) 2. Find the file that relates to the E3, 825-P, or IntelliVAC+ module that is connected to the 2100-ENET unit. 3. In the Details & Download column for the device, select Download. 4. Click Save to save the EDS file your personal computer.
  • Page 8 8 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter 3. Register a single file, browse to the location where the EDS file is located, and click Next. 4. Click Next to accept the installation test results. Rockwell Automation Publication 2100-IN090A-EN-P - February 2012...
  • Page 9: Logix Controller I/O Messaging

    Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter 9 5. Accept the graphic image by clicking Next. 6. Click Next to register the device. 7. Click Finish to successfully register the module. Logix Controller I/O Messaging RSLogix 5000 software is used to configure I/O Messaging between an automation controller and an E3 Plus EtherNet/IP Adapter module on an EtherNet/IP network.
  • Page 10 10 Quick Start Guide for Configuring an E3 Plus EtherNet/IP Adapter 3. Enter a name for the E3 Plus EtherNet/IP Adapter module. The name creates a tag in RSLogix 5000 software that can be used to read and write data from the E3 Plus EtherNet/IP Adapter module.
  • Page 11 For Instance 100, the size is 6. For Instance 103 and 105, the size is 1. The E3 Plus EtherNet/IP Adapter Configuration Assembly Instance is 6. Currently, the 2100-ENET unit does not support the configuration assembly. Output Assembly - Instance 105...
  • Page 12 9. Click Finish to add the E3 Plus EtherNet/IP Adapter module to the I/O Configuration in RSLogix5000 software. Allen-Bradley, Rockwell Software, Rockwell Automation, and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.