4.18 Displaying Data on the Screen and Updating Settings (Data R/W)

In RUN menu, inspection results (judgement, data, execution time, etc.), setting values (parameters of
checkers, etc.), information of PV (calendar, system register value, etc.) can be displayed. This is Data R/W
(Read/Write) function.
The displayed value can be modified for some data.
The data is displayed on the Data R/W sheet. Up to
four sheets of data can be set and displayed per
type and a sheet can show up to 80 items (5
columns x 16 rows).

4.18.1 Setting Data R/W

Register data in Data R/W sheet. The sheet is made up by cells displaying items. Up to 80 cells can be set. (5
columns x 16 rows)
Setting Cell Number of Data R/W Sheet
Set the number of cells by specifying the number of columns and the number of rows. The settable range is 1
column x 1 row to 5 columns x 16 rows.
1.
Select "TYPE" from the menu bar.
The menu appears.
2.
Select "Data R/W".
"Data R/W" setting window is displayed.
3.
Select a sheet number of Data R/W to set.
4.
Press the FUNC key and select "Number of
Cells" from the pop-up menu.
The window to set the number of cells appears.
5.
Enter the number of columns and rows and
then press the CANCEL key.
The specified number of cells are displayed.
The number of cells is counted from the upper left.
When setting the number of columns to "3", the 4th column and after will be deleted even though data has
been registered in them and the data also will be deleted. Note that setting the number of columns to "4"
or more again cannot restore the deleted data.