Panasonic PV500 User Manual page 152

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

Registering into Data R/W
(This is supported in Ver.1.30 or later.)
The detected Area of cells (for Connector (Binary Window)) or Gray Average (for Connector (Gray Window)),
Judgement Limits, and Judgement can be registered into Data R/W from the checker setting window. Although
you can register them also in Data R/W setting window, information of many cells can be registered efficiently
with less operation from the checker setting window.
1.
Select "Data R/W" in the checker setting window.
2.
Select a sheet of Data R/W to register data in
"Data R/W".
3.
Select a direction to arrange the data in
"Rightward/Downward".
Rightward: Registers the data from the specified
position to the right cell.
Downward: Registers the data from the specified
position to the lower cell.
4.
Select the setting table and select a data type to
register.
Result No.:
Cell No. of connector checker
Maximum:
Maximum value of cell judgement
limits
Minimum:
Minimum value of cell judgement limits
Result:
Area or Gray average of each cell
Judgement: Judgement of each cell
In the setting table, always "0" are displayed.
Even after registering the data into Data R/W, the
table shows "0" again.
The table cannot display the current registration
status of Data R/W.
5.
Specify Starting Area, Number of Areas, and No.
Starting Area: Cell No. of the first cell to register.
R/W Row:
The position on a Data R/W sheet of
the first data.
R/W Column:
No. of Areas:
Number of connector checker cells
data of which are registered in Data
R/W sheet.
6.
Press the CANCEL key to go back to the checker
selecting window.
The data is registered at this timing.
When the destination cell of the Data R/W sheet is
already set an expression, the data is overwritten.
Note that the confirmation message does not
appear.
150
The example shown above is the setting where
Judgements of cell No.0 to 3 are registered into
row No.3 and column No.1 to 4 in Data R/W 0. The
data are registered as below.
When Number of Areas is set to 5 under the
condition above, the data that cannot be included
in the specified row are stored in the next row from
the first cell.