Setting Judgement Limits
Set a tolerance (maximum and minimum values) of the values of detected floats and "Distance Difference". If
the floats and distance difference are within the tolerance, the object will be judged as "OK", if they are out of it,
the object will be judged as "NG". When judgement of floats and distance difference are both "OK", judgement
of the checker will be "OK".
"Distance Difference" is a difference between floats of adjacent pins. For example, the distance difference of
No.0 is the difference between the floats of No.0 and No.1.
1.
Select "Judgement Limits".
2.
Input the setting values for "Max. Judge. Pitch" and "Min. Judge. Pitch".
Even when using "Float" as the execution mode, these items are displayed as "Max. Judge. Pitch" and
"Min. Judge. Pitch".
3.
Input the setting values for "Max. Distance Difference" and "Min. Distance Difference".
Enter maximum/minimum values for distance difference.
4.
After inputting is completed, press the CANCEL key.