Character
Displays a maximum of 16 one-byte characters such as inspection results of checkers and system values.
Set the characters to display, display position, character size, number of digits and alignment.
Specifying Characters to Display
1.
Select "Display Character" in "Character" setting window.
A list of available items is displayed. (The items displayed in gray
indicates that they are not unset.)
The data that can be set for each item is as follows.
Checker:
Geometry Calculation:
Numerical Calculation:
Judgement:
System values:
System Register:
Slice Level:
Text:
2.
Select characters to display from the list.
After the selecting is completed, the detail of
the displayed characters is shown in the
upper part of the screen window.
Character Size and Display Base
About Character Size
Specify the vertical size of a character in the
range of 22 to 440 pixels by 22. This size
includes the vertical size of the character, top
and bottom margins.
As shown in the right figure, the horizontal and
vertical sizes of two-byte characters are the
same, however, the horizontal size of one-byte
characters is a half of the vertical size.
About Display Position
Coordinate X,
Refer the coordinate values detected by each checker, results of numerical calculation or
Coordinate Y
values stored in the system registers, or specify specific positions with values or the cursor.
It is also possible to refer the coordinate of the characters that have been set for the
currently setting Character/Figure Drawing checker. However, only the character coordinate
that has been set to the smaller number than the currently setting number can be referred.
Comment of each checker, Inspection
result (*Same as the items that can be
input in Numerical Calculation)
Comment, Inspection result
Comment, Inspection result (Previous
value is selectable.)
Comments of JRC(Internal),
JDC(External), Judgement
Inspection time, Inspection frequency,
Total judgement, Scan count, Type No.
System Register 0 - 7
Maximum and Minimum values of each
slice level group
Character string up to 16 (one-byte)
characters
With PVWIN, you can input the
characters that not on the software
keyboard.
One-byte
characters
11 to 220
Character size x 1/2
Two-byte
characters
Character
size
22 to 440
22 to 440
Character size