Panasonic PV500 User Manual page 211

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

Detecting a Object Size
Binary Edge, Gray Edge, Feature Extraction, Smart Matching and Smart Edge (Line) can be set to detect an
object size in Area Size Adjustment.
Example 1:
Example 2:
Example 3:
If Area Size Adjustment detects multiple parts, the coordinates of No.0 is used to adjust the area.
When there is a possible to detect multiple parts, sort them so that the desired part is always No.0.
Creating a Area Size Adjustment Checker
Although Area Size Adjustment provides No.0 to 999 per type (if the number of used block is 10), the setting
limit is 1000 checkers combined with Position Adjustment.
1.
Select "INSPECTION" > "Area Size Adj.".
2.
Select the checker No. list and specify a
checker (Area Size Adjustment) number to set.
3.
Select a type of Area Size Adjustment to create.
The setting window of the selected Area Size
Adjustment is displayed.
The procedure after here is the same as the checker of
the type that you select to create an Area Size
Adjustment. Refer to the following page for details.
·
Binary Edge: page106
·
Gray Edge: page 110
·
Feature Extraction: page 115.
·
Matching: page 121.
·
Smart Edge (Line): page 183
209

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: