Inspecting In "Execute All" Mode; Inspecting In "Automatic Switch" Mode - Panasonic PV500 User Manual

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

Referring the results of other blocks
In Execute All mode, all the set checkers are executed, however, some blocks are not executed in
Automatic Switch mode or User Defined mode.
When referring the result of other blocks, note that it may not work properly depending on the operation
mode used even though it can be set.
Execute All
Uses the position adjustment set in other blocks, and refers to the operation and judgement
Mode:
results of each inspection checker for the numerical calculation or judgement output of other
blocks. However, if other numerical calculation is referred for numerical calculation or if other
judgement output is referred for judgement output, only the expression with a number
smaller than that of the referred expression can be referred.
Automatic
Refers to the position adjustment set in other blocks, and the operation and judgement
Switch Mode:
results of each inspection checker for the numerical calculation or judgement output of other
blocks. However, it does not work properly when referring to a checker of the block that is
not executed by the same start signal.
User-Defined
Checkers of other blocks can be set to refer. However, as it is only one block that can be
Mode:
executed, it does not work properly if the result of another block is referred.

4.4.2 Inspecting in "Execute All" Mode

The "Execute All" is a factory default execution mode.
This mode executes all set checkers. You do not have to be concerned about "Block" in this mode.
Specifying Execution Mode and Number of Blocks
1.
Select "TYPE" > "Type Setting" from the menu bar.
"Type Setting" window is displayed.
2.
Select "Execution Condition".
3.
Select "Execute All" for "Execution
Mode".
4.
Enter the number of blocks 1 to 10 for
"Number of Blocks".

4.4.3 Inspecting in "Automatic Switch" Mode

Automatic Switch mode inspects multiple blocks orderly. Firstly block No.0 is executed. The result decides the
next operation; proceed another block, execute the next block, or terminate the inspection. These conditions
can be set in Judgement setting window. (Page 77)
In Automatic Switch mode, only the last block to be executed will be output even when multiple blocks are
inspected.(Example of the output through parallel I/O: Pages 272 and 274) Thus, only when a specific block is
executed last, the result can be output to an external device according to the settings of Judgement or
Numerical calculation of the executed block.
Not only judgement and numerical calculation results but also "Total Judgement" (page 247), "Save Image
Memory" and "Image Output" (page 250) are executed according to the condition of the block executed last.
Example)
When inspecting the front and back face of three types of objects
shown on the right, they are identified their type (A/B/C) and top
or bottom, and then inspected as needed.
Front face
Back face
75