5.
Enter an operation expression.
Up to 16 items and 560 characters* can be
set.
If you selected a wrong item, delete it with the
F2 key and reregister the expression.
Moving the cursor onto an item displays the
information of the item in the expression
explanation field.
*) The products before ver.1.1 limit the number
of characters to 256.
6.
Enter a comment with the software
keyboard as necessary.
7.
After inputting is completed, press the CANCEL key.
8.
Press the Cancel key again.
When the dialog message appears, select "YES".
"Yes": Registers the expression.
"No": Returns to the status before inputting the expression.
"Cancel": Cancels registering the expression and come back to status to edit.
When an expression is incorrect such as a grammatical error, even if you select [Yes], a message appears
and registration cannot be executed. Correct the expression in the case.
9.
Press the TRIG key to run a test and confirm the updated judgement as necessary.
Input Example: Entering a Judgement of a Checker
For this example, we enter the judgement of Position Adjustment No.0. Depending on the type of checker,
selectable data varies.
1.
In the list of items that can be entered in an
expression, select "Checker" > "PAC(Position
Adjustment)".
The list of position adjustment is displayed.
2.
Select checker No. 000.
The list of result types is displayed.
3.
Select "Judgement".
The code indicating the judgement of Position
Adjustment No.0 is displayed in the expression field.
Highlighting a code displays the meaning of it in the
bottom field of the screen.