Download Print this page

Gray Scale Edge Checkers; Menu Screen; Checker Setting - Panasonic A230 User Manual

Machine vision system

Advertisement

OCR Type A230

11.1 Gray Scale Edge Checkers

Gray scale edge checkers use gray scale processing for precision detection of changes
in gray scale (outlines, boundaries, etc.). They are capable of detecting edge
coordinates with sub−pixel precision. They can also judge whether or not a product is
OK on the basis of the number of objects detected.
Up to 256 edges can be detected. (However, only up to 99 gray scale edge checkers
can be used for numerical calculation.)
You can set up to 32 checkers per type.
11.1.1

Menu Screen

5
No. (Checker No.)
Set the number of the gray scale edge checker to be created.
1.
Select Camera
Select which camera (A or B) will supply the image on which the gray scale edge
checker is to be activated.
2.

Checker Setting

Set the checking area and set parameters, etc.
3.
Detected Judgment
Set the upper and lower limits for the number of edges detected by the gray scale
edge checker and perform judgment based on those limits.
4.
Positon and Rotation Adjustment Group
Set which position and rotation adjuster will adjust the gray scale edge checker
being created.
5.
Result
Display result information for up to 99 detected edges.
6.
Copy Checker
When creating a checker, copy the data from an existing checker.
7.
Delete Checker
Delete the checker.
Gray Scale Edge Checkers
11.1 Gray Scale Edge Checkers
11 − 3

Advertisement