Panasonic PV500 User Manual page 84

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

6.
Set the parameter for the selected filter.
Set details (Direction, Filter Size, Maximum, and Minimum, etc) as necessary.
Direction is to apply the selected preprocess and the options are X, Y, and X/Y.
7.
Set 2ND to 10TH process as necessary.
When multiple steps are set, PV500 processes from 1ST step in numeric order.
8.
After setting is completed, press the CANCEL key.
As an image displayed in SETUP menu, an image in the mid-course phase of preprocess can be selected.
Press the F1 key and select "Preprocess" from the displayed Image menu.
Copying Preprocess
1.
Highlight the step you want to copy and press the FUNC key.
The pop-up menu appears.
2.
Select "Copy".
3.
Select the step that you want to paste and press the FUNC
key.
The pop-up menu appears.
4.
Select "Paste".
The preprocess is copied.
If a preprocess has been already set in the destination, the message of overwrite confirmation appears.
Selecting "Yes" executes copying the checker.
Disabling the Set Preprocess
(Ver.2.00 or later)
Using this function disables a specified step and enables to execute an inspection or run a test without deleting
the setting.
The invalid/valid setting is saved as type data.
1.
Highlight the step you want to disable and press the FUNC key.
The pop-up menu appears.
2.
Select "Invalid".
The display in the column showing [Step] of the selected step
changes to "----".
In the example on the right, "2ND" changed to "----" to show the
step is invalid. In this case, the image rotation of the third step is
executed after the feature extraction of the first step.
Select "Invalid" from the pop-up menu again to enable the
preprocess in the invalid step.
82