Specifying Checker No.
1.
[Select "Smart Edge (Circle)" in "Checker Type".
2.
Select the checker No. list and specify a checker number
to set.
3.
Press the ENTER key to determine the checker No.
"Smart Edge (Circle)" setting window appears. The gray
image is displayed on the screen window.
Selecting a Camera
Select a camera image to set "Smart Edge (Circle)" checker.
1.
Select "Area Setting" in "Smart Edge
(Circle)" setting window.
2.
Select a camera No. in "Camera".
The image of the selected camera is
displayed.
Select a displayed image type (Live/Memory and Gray/Binary) or magnification in "Image Menu" opened
by pressing the F1 key.
Selecting Position Adjustment
Position Adjustment is helpful when the position of an inspection object may shift largely or an angle can be
detected in advance for an ellipse object.
Select a Position Adjustment checker that has been already set. Refer to page 198 for details of position
adjustment.
1.
Select "Position Adj." in Area Setting window.
The list of position adjustment is displayed.
If a position adjustment checker is not created, "Position Adj." cannot be selected.
2.
Select a Position Adjustment No. from the list.
When selecting a checker number for Position/Rotation Adjustment or Rotation Adjustment, the criterion values
for maximum and minimum angles or the label for the horizontal axis of the graph vary depending on the setting
of "Base Angle". Refer to page 177for details.