Inspection Time and Inspection Cycle
Executing an inspection shows "Inspection Time" or both of
"Inspection Time" and "Inspection Cycle" in ms units in the lower
left of the screen.
Inspection Time
When "Inspection Process" is set to "Serial", Inspection Time
equals "READY signal OFF time" which is the time from START
signal input to I/O output.
When you output data to COM.0 port, Ethernet port, or a SD
memory card, or when you output inspection images in
"Synchronous" method, Inspections Time is the time from Start
signal input to completion of the data output.
Inspection Cycle
The time from the I/O output of the previous
inspection to the I/O output of the current
inspection. It is displayed only when "Inspection
Process" is set to "Parallel".
When you output data to COM.0 port, Ethernet port,
or a SD memory card, or when you output
inspection images in "Synchronous" method, it is
the time from the completion of the previous
inspection data output to the completion of the
current inspection data output.
*1) The time of Image Capture includes the time of capture delay.
*2) When the data is output in several times, it indicates the I/O output to the last one.
315