Smart Edge (Line) (Horizontal), Smart Edge (Line) (Vertical)
The angle of the approximate line detected in the same method of Smart Edge (Line) is considered as the base
angle. The base coordinate is the intersection point of the line passing through the center of the inspection area
and the approximate line.
4.8.3 Setting a Position Adjustment
Selecting a number and a type of Position
Adjustment
1.
Select "INSPECTION" > "Position Adj.".
2.
Select the checker No. list and specify a Position
Adjustment checker number to set.
3.
Move the cursor onto a type of Position
Adjustment to create.
The list of detection methods available in the
selected Position Adjustment is displayed.
4.
Tilt the ENTER key right and then up/down to
select a detection method.
The setting window of selected Position Adjustment
is displayed.
Selecting a Camera
Select a camera image to set Position Adjustment.
1.
Select "Checker Settings" in "Pos. Adj." setting
window.
2.
Select a camera No. in "Camera".
The image of the selected camera is displayed.
Select a displayed image type (Live/Memory and Gray/Binary) or magnification in "Image Menu" opened
by pressing the F1 key.