Cause of Turning on ERROR 1 Signal
Cause
The following errors when sending a command to PV500.
•
BCC (Block check code) error
•
An undefined command was sent.
(including the case of sending a part of command such as only
delimiter(CR))
Command receive buffer overflow of PV500
Communication error (communication timeout or sum check error)
occurred during PLC communication.
While PV500 stops the operation, a command to execute one of
the following is sent.
•
Type switch
•
Save the setting data (in the storage space in PV or a SD
memory card)
•
Read the setting data (from the storage space in PV or a SD
memory card)
•
Save images saved in the save image memory to a SD
memory card
•
Clear the save image memory
•
Print screen
•
Reset statistics
•
Layout change
•
Read or write parameters
•
The specified product number does not exist.
•
Other number than 000-255 was specified for a product
number.
Timeout of Type Switch/ Read Setting Data
When waiting for Individual Trigger input*, image capturing of the
rest of the cameras or Abort Inspection/Process is not executed in
10 seconds after sending the signal or command to execute above
operations. (This condition does not apply when Individual Trigger
Timeout is set to "Yes")
* The status where the device is waiting for the rest of camera
triggers after receiving some of the camera triggers.
Other number than 00-99 was specified as an area number when
saving or reading setting data to or from PV or a SD memory card.
When reading setting data from a SD memory card;
•
No SD memory card is attached or cannot be
accessed.
•
No data file in the designated area of a SD memory
card.
•
The data file is not data of PV500.
•
The data file is incompatible. (Data of the later version,
etc.)
•
The number and types of cameras connected to
PV500 is different from the Camera setting of the data
file. (Example: Camera was disconnected
unexpectedly.)
When saving setting data in a SD memory card;
•
No SD memory card is attached, the card cannot be accessed,
or used up its capacity.
•
The SD memory card is write-protected.
•
The file with the specified storage number already exists, and
the property of the file is "Read-only".
Error
Solution, etc
Code
E0100
E0110
Decrease commands to send to
PV500.
E0111
Connect and set correctly.
E0200
Operate (run) PV500 and
execute again.
E0210
Specify a type number correctly.
E0211
Input the trigger signals of the
rest of cameras or abort
inspection/process.
E0212
E0213
Check attachment of the SD
memory card or presence of
data file.
E0214
Prepare a correct data file.
E0216
Correctly attach a SD memory
card which is writable and has
enough free space.
375