Panasonic PV500 User Manual page 184

Machine vision system imagechecker
Hide thumbs Also See for PV500:
Table of Contents

Advertisement

Running a Test and Confirming Result
Confirm if the current settings perform an inspection properly. To observe the image or checker pattern easily,
set "Window Transparency (SETUP menu)" to a larger value.
("Change Window Transparency (SETUP Menu)", page 341 )
1.
Press the TRIG key.
When a live image is displayed on the screen, PV captures a new image first and runs a test. When a
memory image is displayed, it runs a test using the current memory image without capturing any images.
Position adjustment and area size adjustment are also executed if they have been set.
2.
Check data of detected area list.
Check the graph, data of virtual circle, measurement data and judgement result to be displayed on the
screen.
Error messages when running a test
If Smart Edge (Circle) is not performed properly when running a test, error numbers and messages are
displayed in the checker list.
Error No.
Message
0040
Virtual circle cannot be
calculated.
0041
Edge required for
measurement cannot be
detected.
182
Cause
When the number of detected edges is 2 or less:
When the center of virtual circle is not within the
range of -9,999.999 to +9,999.999.
When all the detected edges are located on the
same line:
When edge count is 0 after denoising:
When no combination of edges to be paired
cannot be detected when Detect Mode is Diameter
measurement or Width measurement: