Cause
During continuous inspection, the signal to execute "Reinspection"
is input or the command is sent.
Although a command (except PIO) to be activated by checking that
the READY signal is on was requested, it was not accepted more
than one second because the READY signal was off (e.g. Detect
trigger or Continuous inspection start was processing, or setting
data was being saved to the PV).
When you make Template setting with the following conditions;
It was executed when SETUP menu was displayed.
It was executed when Detect trigger was processing or
Continuous Inspection was used.
It was executed during parallel I/O output when setting "Area
Display" to "Yes".
While "Area Display" is set to "Yes", the command for Send 2
(%A) was sent when Send 1 was supposed to.
While "Area Display" is set to "Yes", the command for Send 1
(%Accc,??) was sent when Send 2 was supposed to.
While "Area Display" is set to "No", the command "%A" was
sent.
The specified number of checker or template is not create.
Other number than 000-999 for checker number, or 00-63
for template was specified.
Template cannot be set because no image has been
captured after PV500 started up when you select "Use the
Last Image" for "Template Setting.
No feature on the image of template registration area.
An error occurs in Position adjustment when you use it.
Template registration area is outside of the captured image
(image partially captured when executing partial imaging).
When the latest inspection image could not output to Ethernet
interface when "ERR signal ON at Output Error" is set to "Yes";
Ethernet communication cannot be established (with
connection problems including disconnection).
Image Receiver is not activated.
Parallel Handshake Timeout occurred.
(No ACKNOWLEDGE signal indicating that the external device has
received data was input to PV500 within the Timeout.)
374
Error
Solution, etc
Code
E0204
You cannot reinspect during
continuous inspection.
E0205
E0230
Operate PV500.
Stop Detect trigger and
Continuous Inspection, and
then execute Template setting.
Execute Template setting after
the completion of parallel I/O
output.
Enter a command correctly.
E0231
Specify a correct checker
number or template number.
E0232
Execute an inspection, or
change the setting to "Capture
New Image" to execute
Template setting.
E0233
Check the captured image.
Adjust the whole registration
area to be in the range of the
captured image.
E0255
Correctly connect Ethernet.
Activate Image Receiver, and
set it to "CONN: Standby".
---
Input ACKNOWLEDGE signal
within Handshake Timeout.