B. Parameters and data of the CPX terminal
Module diagnostic data: Number of the first faulty channel
Function no.
2008 + m * 4 + 0;
Description
Specifies the number of the faulty channel (bits 0...5)
Bit
Bit 7
Values
Bits 0...5 : 0...63
Bit 6
Bit 7
Note
With the aid of the module number of the faulty module (see system diagnostic
data, byte address 1937) you can ascertain the function numbers of the relevant
diagnostic data.
Tab. B/43: Number of the first faulty channel
Module diagnostic data: Module error number
Function no.
2008 + m * 4 + 1;
Description
Error number
Bit
Bit 0 ... 7 : error number
Values
0 ... 255
Note
See section 5.2.3 for possible error messages.
Tab. B/44: Module error number
Module diagnostic data: Information 2 (reserved)
Function no.
2008 + m * 4 + 2;
Description
Reserved
Tab. B/45: Information 2 (reserved)
Festo P.BE−CPX−SYS−EN en 0902e
6
5 ... 0
: Description
0
0
0 ... 63 : No. of the 1st faulty O channel
1
0
0 ... 63 : No. of the 1st faulty I channel
0
1
0 ... 63 : Module error
1
1
0 ... 63 : Reserved
(channel number)
: 0...1
: 0...1
(error number)
m = module number (0 ... 47)
m = module number (0 ... 47)
m = module number (0 ... 47)
B−35