5.2.2 Waste water connection for units without WaveClean

36
If the waste water outlet is connected to a customer-supplied siphon (1),
counter pressure may cause the siphon in the unit (3) to overflow.
Therefore, the waste water pipe must be fitted with an aerator in this case.
A PA-I 1818 DIN 19560 HT pipe is recommended for the connection to
the waste water system.
The diameter of the waste water pipe must not be reduced.
CAUTION
Damage caused by an incorrect water connection
→ Do not operate the unit without an aerator in the waste water pipe.
1. Make sure that customer-supplied pipes meet the requirements for
the waste water connection (see
water", Page
17).
2. Observe the provisions for the disposal of waste water (see
"Waste water", Page
3. Connect the unit to the waste water system using a heat-proof pipe
(DN 50).
4. With customer-supplied siphons: connect aerator to a waste water
pipe.
5. With customer-supplied siphons: pour 2 quarts (2 l) of drinking water
into the siphon.
This ensures the siphon will work properly.
CAUTION
Risk of damage by waste steam
→ To protect the unit from damage caused by waste steam, the funnel
must not be positioned below the unit.
NOTICE
Units without WaveClean are supplied without a built-in overflow.
Therefore, they may only be connected to the waste water system via
an open drain in a funnel.